Reply To: Calculating Cpk/Ppk on True Position with Bonus Tolerance

@John-Moore – use the maximum material condition to establish your upper spec limit, with your lower spec limit being zero (perfectly centered, perfect size).

View Article



Calculating Cpk/Ppk on True Position with Bonus Tolerance

Is there a method that I can use to calculate Cpk on a true position requirement that has MMC (bonus tolerance)? The specification is 0.05 mm with bonus tolerance applied to the feature and datum. The...